Synchronize with Caller ID1

Synchronize  with  Caller  ID1 This  function, when  enabled,  synchronizes  the  real-time  clock  with  Caller  ID  (CID) messaging:  call processing  compares  the time  of  a CID message to  the system  real-time  clock and,  if  the  difference  is more  than  two minutes,  resets  the real-time  clock to  match the  time  (minutes)  of  the CID message.  The system  will  analyze  each  such  message  (or  —  if it receives  more  than  four  calls  with  CID  information within  a one-minute  period  —  as  is  needed).  Select  ENABLE  or  DISABLE  by  pressing a scroll  key  (either  or ). Choosing  ENABLE  will  allow  the  CID  data  to  update  the  time  and  date. Default:  Disabled. Esi-Link-related  notes  (see also  “Function 83:  Esi-Link  programming,”  pages  M.9–M.10): If  “synchronize  with  Caller  ID”  is  enabled,  Esi-Link  time synchronization  (from location 700)   will be disabled.   If  “synchronize with  Caller  ID”  is  disabled,  Esi-Link  time  synchronization  will  be  allowed (minutes  only). When Esi-Link  is used,  all  cabinets’  time will be  synchronized by cabinet  700,  unless  “synchronize with  Caller  ID”  is  enabled in Function 142. 2:   Adjust for  Daylight  Saving  Time This  function,  when  enabled,  causes  the real-time  clock to  adjust  itself  automatically  for  Daylight  Saving Time  (DST). Select  AUTO  or  DISABLE  for  DST  by  pressing  a  scroll  key (either  or DISABLE  is  best  for  those  areas that  don’t  observe DST. Default:  Disabled.