CO lnes

CO line connection Note:  For  greatest  simplicity,  this  section mentions  each  port  card  without  the use of  an “ESI,”  “E2-,“  or  “CS-“ prefix,  as  cards  otherwise  are  functionally  identical  —  e.g.,  we  refer  to  an  E2-684  or  CS-684  as  just  a  “684.” Local  loop An ESI  Communication  Server’s  advanced  CO  line  circuitry provides  for open loop  detection  and the system’s  built-in  Caller  ID  interface.  Loop  start  lines  are  connected via  the  last  6  pairs  on each  66  block  on  the 612 and 684  cards.  Note:  Observe  correct  order  of  connection to  preserve  proper  rotary  hunting  of  the CO  lines. T1/PRI For  T1 or  PRI  applications  (only  PRI on  the  ESI-50; it doesn’t support  T1),  an  ESI  Communications  Server can use a  compatible  digital  line  card  (DLC)1: •  ESI-1000,  ESI-600,  ESI-200,  ESI-100 —  DLC  and  DLC12,  each  for  either  T1  or  PRI. •  ESI-50  —  DLC82  for  only  PRI. Depending  on  how  you configure it,  each  supports  either  (a.)  a  single  T1 circuit  at  24  DS0 channels or  (b.)  a PRI  circuit  supporting  23  “B”  (bearer)  channels  and  one “D”  (data link)  channel.  The DLC12 and  DLC82 each also  support  12  digital  stations.  The  T1 or  PRI  line is  connected  via the  last  two pairs  of  the industry-standard 50-pin  amphenol  cable  connector  on  the front  of  the  DLC. Each  ESI  Communications  Server  has  a  different  maximum  number  of  system-wide  DLCs  (see  “Port  card options,”  page  A.4).  Partial  T1  or  PRI  applications  are supported  through  line  programming. Each DLC has built-in  CSU  functionality.  The  integrated  CSU  can be enabled  or  disabled  via system programming2.  The following functionality is  provided:  line,  payload,  DTE  and none  (normal  operation) loopback  modes  with  the  ability  to  respond  back  controlled  via  system  programming;  alarm  conditions,  and both  ANSI  T1.403  and  TR  54016  performance messages  for  ESF only.  Important:  On  the ESI-50,  the DLC82 may be installed in  only  slot  2. If  you’re  installing more  than one  T1  or  PRI,  the  DLC  in the lowest  number  slot  will synchronize (“slave”) the system  with  the public  network.  The system will  synchronize  to  only one clock  source.  Therefore,  ESI strongly  recommends  that  the first  DLC  in the  system be connected to  the  T1  or  PRI  that’s connected either  to  the local  CO  or  the nationwide long-distance provider,  either  of  which typically will provide  veryhigh-accuracy  clocking (Strata 3).  The DLC  doesn’t  provide master  or  sub-master  clocking for  privatenetwork  T1  spans.