Administrator Security
Code Control See Security Code. Voice Mail
Alternate Next Call
Routing Mailbox See Next Call Routing Mailbox. Voice Mail
Announcement Mailbox Mailbox that allows a recorded greeting to play to callers. Automated Attendant
Announcement Message The message that the System Administrator records for a specific Announce-
ment Mailbox. Automated
Attendant
Answer Table Determines how the Automated Attendant answers outside calls on each trunk, according to the time of the day and day of the week that the call is ringing.
Automated Attendant
Answering Schedule
Override Enables an alternate greeting and alternate dialing options for callers. Automated
Attendant
Auto Attendant Direct to Voice Mail
Auto Attendant Direct to Voice Mail sends Automated Attendant calls directly to Automated an extension user's mailbox. Their phone does not ring for calls from the Auto- mated Attendant.
See Greeting in this glossary.
Attendant
Auto Erase or Save When a mailbox user completely listens to a new message and then exits their
mailbox, InMail either automatically archives or deletes the message. Voice Mail
Auto Time Stamp After a user listens to a message, InMail can optionally announce the time and
date the message was left. Voice Mail
Automated Attendant The Automated Attendant can automatically answer the telephone system incoming calls, play an Instruction Menu message, and provide dialing options to callers.
Automated Attendant
Automated Attendant Transfer
While on a trunk call, an extension user can transfer the trunk call to the Auto- mated Attendant so the caller can use the Automated Attendant dialing
options. Voice Mail
Automatic Access to VM by Caller ID
InMail mailbox can be associated with a specific caller ID (CID) number. When the CID number is presented to the InMail it will automatically log the user into
their mailbox. Voice Mail
Automatic Call Routing
to a Mailbox See Go to a Mailbox in this glossary. Automated
Attendant
Automatic Message
Erase/Save See Auto Erase or Save in this glossary. Voice Mail
Automatic Routing for
Rotary Dial Callers If an Automated Attendant caller does not dial any digits, InMail automatically
routes them to a specified option (such as the operator or a mailbox). Automated
InMail
Warning tones
The system can broadcast warning tones to a trunk caller, warning the caller that he has been on the call too long. If he chooses, the caller can disregard the tones and continue talking. The outside caller does not hear the warning tones. Warning tones do not occur for Intercom calls and most incoming trunk calls. DISA trunks can also have warning tones. Warning tones are not available to analog Single Line Terminal (SLT) users.
W There are two types of warning tones: Alarm Tone 1 and Alarm Tone 2. Alarm Tone 1 is the first set of tones that occur after the user initially places a trunk call. Alarm Tone 2 broadcasts periodically after Alarm Tone 1 as a continued reminder. Each alarm tone consists of three short beeps.
If programmed, DISA calls are disconnected unless the continue code is entered by the user. With the Long Conversation Cutoff feature, incoming or outgoing central office calls can also be disconnected.
Warning Tone for DISA Callers
For DISA callers, with this feature enabled, the warning tone timer begins when an incoming DISA call places an outgoing call and either the inter-digit timer expires or the outgoing call is answered.
If an outside call is transferred to forwarded off-premise using an outside trunk, the warning tone timer
Toshiba
access codes CO line, 33 feature, 21 speed dial, 37 access DISA, 4 account codes revision, 29 verified, 31 auto attendant, 1, 4 announcement recording
recommendations, 4 CO line assignments, 2 dialing plan, 3 menu, 3 system dialing plan, 3 automatic station relocation physically, 13
swap buttons/features, 13
C
CAMA trunk calls, 6 CO lines, 4
access codes, 33
auto attendant assignments, 2 codesfeature access, 21
paging group, 35 speed dial access, 37 toll restriction override, 29 traveling class, 29 verified account, 31
D
day 2 mode, 8 day mode, 8 day/day 2/night modes, 2, 4, 8 default DNs, 3
dial pad key equivalents, 16 directories, 39
speed dial memo, 40 user name/number, 39
DISAaccess, 4
outgoing calls, 3 security code, 1, 4 cancel, 5 enter/change, 5, 6
E
emergency 911 calls, 6 equipment notes, iii
F
feature access codes, 21 flash button, 24
LLCD name/number information
clear, 18 enter, 17 erase, 18 other stations/devices enter name/number, 18 erase name/number, 20 linked speed dial example, 26
Mmemos, 15
messages, 15
multiple announcement machine, 4
Nnames, 15
night mode, 8
night transfer, 1, 2, 8 enable/disable, 8 lock mode, 9 lock/unlock password, 8
assign/change, 9 routing (ringing) patterns, 8 non-LCD telephones, 17
P
page button, 19, 28, 29 paging group codes, 35 primary announcement, 2, 4
R
records, 39
telephone location, 41 relocation by special dial, 14
S
secondary announcement, 2, 4 setting date/time/day, 1, 10, 11 soft keys, 1, 12, 18, 27 to turn off, 12 to turn on, 12 speed dial, 20, 26 access codes, 37 accessing stored number, 21 advanced features, 21 checking a number, 29 clearing an entry, 21 dialing, 28 flash, 24 long pause, 24
number linking, 24 example, 26 store CO line access code, 26 use new link, 26 pause and flash storage, 24 storing a feature, 20 storing system speed dial number in a
system speed dial code, 20 system numbers, 20 view, 28
station (directory) number, 3 station relocation, 1, 12 automatically relocate, 13 relocation by special dial, 14 systemauto attendant dialing plan, 3
messages, names and memos, 1, 15 setting parameters, 1
speed dial memo numbers, 1 speed dial numbers, 20
Ttelephone location record, 27
tenant service, 8
toll restriction override, 1, 29 add/delete/change, 29 by system speed dial, 26 delete, 30
traveling class codes, 1, 29 add/delete/change, 29 delete, 30
Uuser LCD name/number display, 17
clear, 18 erase, 18 other stations/devices enter name/number display, 18 erase name/number display, 20 write, 15
V
verified account codes, 1, 31 add/change, 31 delete, 32
W
writeLCD memos, 15
LCD messages, 15
LCD name/number displays, 15
NEC systems
PBX SYSTEM DESIGNATION
PBX system is usually designated as “PBX” or “system”.
When we must draw a clear line between the PBX systems, they are designated as follows.
SV8300 : UNIVERGE SV8300 SV8500 : UNIVERGE SV8500 SV7000 : UNIVERGE SV7000 2000 IPS: NEAX 2000 IPS INTERNET PROTOCOL SERVER 2400 IPX: NEAX 2400 IPX Internet Protocol eXchange
ATTENDANT CONSOLE NAME
Attendant Console is usually designated as “Attendant Console”.
NEC’s UNIVERGE Desktop IP
The right phone for every work situation
With the speed of business today, the importance of the desktop phone has never been greater. Today’s employee requires an accessible communication tool at any location in order to be as effi cient and productive as possible. But, many businesses and employees have not taken advantage of the enhanced capabilities offered by today’s next-generation phones. NEC’s UNIVERGE Desktop IP and Digital terminals and handsets are the answer.
With a wide range of customizable features and a modular design, this terminal can help meet the communications needs of any workplace.
Freedom of choice
UNIVERGE Terminals give you the freedom to tailor your platform and telephony applications to meet your business’s evolving needs. Whether your business is just getting started or is already rapidly growing, NEC provides the right solutions.
Personalized terminals to meet your specifi c requirements
NEC’s innovative terminal design delivers maximum deployment fl exibility. Modularity allows for multiple combinations to fi t any business niche or personalization requirement, from the front desk, to the conference room, to knowledge workers, to remote workers, to executives.
Easy-to-use, intuitive interfaces
NEC’s terminal interfaces are designed to improve the overall user experience. The NEC terminal interfaces are designed
to be intuitive, no extensive training is needed. Global icons indicate status at a glance including notifi cation of new voice or instant messages, missed calls, the telephone user’s current presence status, and the device’s current data protection mode.
Personal, system and corporate directories
Quick access to directories; each entry in the directory is searchable, and a call can be placed from the searched entry. Name display on incoming calls, if the Caller-ID matches the registered phone number with the entry in the directory.
Good reasons to choose UNIVERGE® terminals
• Modular construction - the interchangeable design provides easy and cost-effective upgrades, helping to future-proof this businesses investment
• Customizable design - choose from a range of add-on line key modules, faceplates, LCDs, keypads and even printable side panels
• Customizable function keys - can be adapted to the exact individual requirements of a business
• User-friendly interface - little or no staff training required
The UNIVERGE®
The UNIVERGE® SV8100 is a unique communication solution for up to 500 extensions. It improves business performance signifi cantly by making an entire workforce more reachable wherever they are based.
Part of the UNIVERGE®360 portfolio, the SV8100 creates ‘360-degree communication’ encompassing fi xed, mobile and converged communication such as e-mail, Presence and instant messaging. Executives have real-time access to a full circle view of their business; managers easily communicate with team members and supervisors; sales people have immediate access to the data and resources they need to do their jobs anywhere they are.
In short, it makes Unifi ed Communications a reality.
Why NEC?
• A leading global enterprise telephony solution provider
• Empowering our customers through over 100 years of experience in IT and Networking
• Spanning the full spectrum of ICT products and solutions
• Investing over 2,7 billion Euro in research and development every year
• Employing more than 150,000 people worldwide
• The only global company in the world’s top 5 in both computers and communications
• Unsurpassed technical support and logistics
• A reliable, stable partner with the mission to realize an information society friendly to humans and the earth
T1 PRI parameters
Trunk Parameters
· Switch Type: Default = NI2
Options 4ESS, 5ESS, DMS100 and NI2.
· Provider: Default = Local Telco
Select the PSTN service provider (AT&T, Sprint, WorldCom or Local Telco). When set to AT&T, an additional AT
& T Provider Setup menu can be accessed from the menu. 90
· Test Number:
Used to remember the external telephone number of this line to assist with loop-back testing. For information only.
· Send Redirecting Number: Default = Off
· Clock Quality: Default = Network
Leave as Network unless advised otherwise by Avaya.
· Framing: Default = ESF
Selects the type of signal framing used (ESF or D4).
· CRC Checking: Default = On Turns CRC on or off.
· Zero Suppression: Default = B8ZS
Selects the method of zero suppression used (B8ZS or AMI ZCS).
· CSU Operation:
Tick this field to enable the T1 line to respond to loop-back requests from the line.
· Line Signaling: Default = CPE
The field can be set to either CPE (Customer Premises Equipment) or CO (Central Office). This field should normally be left at its default of CPE. The setting CO is normally only used in lab back-to-back testing.
· Haul Length: Default = 0-115 feet
Sets the line length to a specific distance.
· Channel Unit: Default = Foreign Exchange
This field should be set to match the channel signaling equipment provided by the Central Office. The options are Foreign Exchange, Special Access or Normal
Electra Elite IPK Multiline Terminals Hands free
Full Duplex Handsfree
___________________________________________________________________________________
FEATURE DESCRIPTION
The HF-R Unit is an add-on device to the Electra Elite IPK Multiline Terminals that provides a full duplex speakerphone for small conference rooms. An external microphone is also provided that has a locking push-to-mute control button to turn the microphone off.
SYSTEM AVAILABILITY
Terminal Type:
All Electra Elite IPK Multiline Terminals with an HF-R Unit installed
Required Software: R1500 or higher
Required Components: HF-R Unit
AC-R Unit (AC Adapter)
OPERATING PROCEDURES
To use the HF-R using an Electra Elite IPK Multiline Terminal:
1.Press E , and make an internal or external call.
2.When muting is desired, press the Mute key on the external microphone. To cancel muting, press the Mute button again.
Attenfant Station
Attendant Station Outgoing Lockout allows an Attendant Position with an Attendant Add-On Console to be used to set a predetermined Code Restriction Class Assignment at any station assigned on the Attendant Add-On Console. This allows an Attendant to set/reset a restriction to allow/deny an outgoing call.
ISDN (PRI)
ISDN (PRI), Answering Calls
Primary Rate Interface (PRI), Answering Calls
Description
The system provides flexible routing of incoming PRI calls to help meet the exact site requirements. This allows PRI calls to ring and be answered at any combination of system extensions. Many of the options available to incoming analog trunk calls are also available to incoming PRI calls.
Delayed Ringing
Extensions in a Ring Group can have delayed ringing for PRI trunks - just like other types of trunks. If the PRI trunk is not answered at its original destination, it rings the DIL No Answer Ring Group. This could, for example, help a secretary that covers calls for their boss. If the boss doesn’t answer the call, it rings the sec- retary’s phone after a programmable time.
Calling Name Delivery
If provided by the telco, and depending on the version of your system software, the system can support call- ing name delivery in the Facility Information Element. With this information available, display telephone users can see the name of the calling party.
Caller ID
With Caller ID enabled, the system will provide information for ISDN calls that do not contain the Caller ID information. If the Caller ID information is restricted, the telephone display will show “PRIVATE”. If the system is not able to provide Caller ID information because the telco information is not available, then the display will show “OUT OF AREA”.
SMDR Includes Dialed Number
The SMDR report can optionally print the trunk’s name (entered in system programming) or the number the incoming caller dialed (i.e., the dialed ISDN digits). This gives you the option of analyzing the SMDR report based on the number your callers dial. (This option also applies to a DID trunk as well.)
Calling Party Number Notification
The system can provide calling party number notification for outgoing ISDN calls. When a call is made on an ISDN line by an extension, the system will send the identification for the extension placing the call, if it’s programmed. If there is no Extension Calling Number assigned, the system will send the calling number for the ISDN trunk. If both the extension and trunk information is programmed, the extension information will be sent as it takes priority.
When the option for calling party subaddress is on, the extension number will be sent as the subaddress infor- mation. Both the calling party number and calling party subaddress are sent in a SETUP message as the calling party information element and a calling party subaddress information element. Allow the system to send the subaddress by setting the following programs: 10-03-05=1, 15-01-04=1, 20-08-13=1, 21-13-01=enter number to be sent.
Calling Line Identification Presentation
CLIP display available with software 1.02+.
A Class of Service option has been added which can be used to allow the Calling Party Number IE in the Setup Message.
Calling Party Allowed or Prevented for Extension
Calling Party allowed for extension with software 1.04+.
The system allows the Calling Party Number for outgoing ISDN calls based on the extension’s set up in Pro- gram 15-01-04 : Basic Extension Data Setup - ISDN Caller ID. If this option is to be enabled, then
PcPro WebPro
In addition to the keyset programming, the Aspire system provides the ability to use a PC to access system programming. The Windows-based PCPro and the HTML-based WebPro allows you to:
● Edit the telephone system programming options from a remote location.
The PCPro application requires changes to be uploaded to the system before they take effect. The WebPro application applies the changes as soon as the APPLY or OK icon is clicked. ● Access system maintenance functions (like reports and tests).
In addition, PCPro allows you to:
● Save your programming to your PC’s hard disk - then upload it via a LAN (Local Area Network), PPP, serial or USB connection.
PPP is a protocol that allows a computer to use a regular telephone line and a serial interface (modem) to make TCP/IP connections.
Local programming is possible using the LAN, USB or serial connection (the USB connection is not avail- able on the Aspire S) (CTA and CTU adapters cannot be used). Remote programming is possible using the dial- up serial port connection or LAN connection provided there is internet/network access to the IP address of the CPU.
● Download the existing programming in the telephone system via a LAN, PPP, serial or USB connection - and save it to your PC’s hard disk.
● Set up a default database with the settings you use most often.
● Create a unique database for each phone system you have installed. Since you save the site-specific data to your PC’s hard disk, you can easily retrieve a customer’s programming if something goes wrong.
Aspire S/Aspire System Requirements
● Aspire S system software 2.50 or higher ● PCPro: NTCPU LAN, Serial or USB Connection or any version of Aspire system software to PC (USB on Aspire M/L/XL Only)
● Aspire S: ENTU for LAN Connection WebPro: TCP/IP via LAN Connection to PC
PCPro PC Requirements
● CPU: Pentium II 500 MHz equivalent or higher ● 128Mb of RAM
● 20Mb of Hard Drive Space ● Monitor Resolution: 800 x 600 pixels or higher ● Mouse ● Microsoft Windows 2000/XP
● Internet Browser: Internet Explorer 6.0 or higher or ● Network Interface Card (NIC) Netscape 6.0 or higher (depending on connection type)
WebPro PC Requirements
● CPU: Pentium III 600 MHz equivalent or higher ● Monitor Resolution: 800 x 600 pixels or higher ● Mouse ● Microsoft Windows 2000/XP
● Internet Browser: Internet Explorer 6.0 or higher or ● Network Interface Card (NIC) Netscape 6.0 or higher (depending on connection type)
Hold
Hold lets an extension user put a call in a temporary waiting state. The caller on Hold hears silence or Music on Hold, not conversation in the extension user’s work area. While the call waits on Hold, the extension user may process calls or use a system feature. Calls left on Hold too long recall the extension that placed them on Hold. There are four types of Hold:
● System Hold
An outside call a user places on Hold flashes the line key (if programmed) at all other keysets. Any keyset user with the flashing line key can pick up the call.
● Exclusive Hold
When a user places a call on Exclusive Hold, only that user can pick up the call from Hold. The trunk appears busy to all other keysets that have a key for the trunk. Exclusive hold is important if a user doesn’t want a co-worker picking up their call on Hold.
● Group Hold
If a user places a call on Group Hold, another user in the Department Group can dial a code to pick up the call. This lets members of a department easily pick up each other’s calls.
● Intercom Hold
A user can place an Intercom call on Hold. The Intercom call on Hold does not indicate at any other extension.
With Automatic Hold enabled (Program 15-02-07), when the user is on an outside call using the handset, the user can press a flashing line/loop key to answer an incoming call without disconnect- ing their first call. The first caller is automatically placed on hold. This feature does not work using handsfree or when the user is on an ICM and presses a flashing line/loop key (the ICM call is disconnected).
Hold Recall to Operator
Hold Recall to Operator enhances how the system handles calls that have been left on hold too long. With Hold Recall to Operator:
● A trunk call recalls the extension that placed it on Hold after the Hold/Exclusive Hold Recall time.
● The recalling trunk will ring the extension that placed it on Hold for the Hold/Exclusive Hold Recall Callback Time.
● After the Hold/Exclusive Hold Recall Callback Time, the trunk call will ring the operator.
Hold Recall to Operator applies to trunk calls placed on System Hold, Exclusive Hold and Group Hold. It does not apply to Intercom calls.
Conditions
The called extension must lift the handset or press the SPK key before the call can be placed on hold.
Default Set
Computer Telephony Integration (CTI)
Computer Telephony Integration (CTI). It uses the Telephony Application Programming Interface (TAPI) 2.1 protocol. To allow CTI an Ethernet inter- face is present on the NTCPU.
TAPI 2.1 based CTI realises third party call control features such as ACD, Predictive Dialing, and Call Routing.
General Description
The following section assumes you have installed the Aspire TSP. This section contains further infor- mation on configuring TAPI2.1 on Windows NT Server.
The following information is provided:
• Aspire TSP Configuration
• Enabling TAPI Server
• TAPI Server User Administration
Aspire WebPro
WebPro
The WebPro software is installed on the Aspire NTCPU PCB - there is no separate software installation. This means that when the Aspire system software is updated, the WebPro software is updated as well.
Make sure the SW3 switch on the Aspire NTCPU (switch just above the serial port connector) is set to OFF (down).
The Aspire system (Program 10-21-02) and the Dial Up setting must be set to use the same baud rate (19200 by default).
Make sure the PC is connected to the serial or USB port on the Aspire NTCPU with a null modem (cross- over) cable. For LAN connections, use a straight-through cable if connected through a hub. If connected directly to the Aspire S/Aspire LAN connector, use a cross-connect cable.
The WebPro software provides a Help system if you experience difficulty in using the program. Simply press the ‘F1’ key.
1.Make sure the required cable (USB, serial, LAN) is connected from the PC to the Aspire S/Aspire system. 2.When using a LAN connection, skip to Step 5.
When using a connection other than a LAN, you must first connect to the Aspire using the dial-up connection. If not already connected, click on START SETTINGS NETWORK CONNECTIONS select the dial up connection to be used to connect to the Aspire system.
3.In the window that appears, if the user name and password are acceptable, click CONNECT or DIAL depending on your connection type.
Only one person is allowed in programming mode at a time. An error message will be received if trying to log in while another user is already in programming mode.
4.If the PRE-DIAL TERMINAL SCREEN option was selected in the dial-up setting, when it appears, left click on the black area of that screen. Type AT and press ENTER. Once OK has been displayed, click on CONTINUE and wait for the computer to connect to the Aspire system.
If an OK does not appear on the screen, continue to type AT and then press enter until you get an OK on the screen.
5.Once the connection has been established, with either Internet Explorer or Netscape Navigator installed, open the internet
browser application.
6.Enter the IP address of the Aspire system (example: http://192.78.0.1). This address is selected based on the type of con- nection to the Aspire.
N 47
WebPro
WebPro
Using WebPro
The WebPro software is installed on the Aspire NTCPU PCB - there is no separate software installation. This means that when the Aspire system software is updated, the WebPro software is updated as well.
Make sure the SW3 switch on the Aspire NTCPU (switch just above the serial port connector) is set to OFF (down).
The Aspire system (Program 10-21-02) and the Dial Up setting must be set to use the same baud rate (19200 by default).
Make sure the PC is connected to the serial or USB port on the Aspire NTCPU with a null modem (cross- over) cable. For LAN connections, use a straight-through cable if connected through a hub. If connected directly to the Aspire S/Aspire LAN connector, use a cross-connect cable.
The WebPro software provides a Help system if you experience difficulty in using the program. Simply press the ‘F1’ key.
1.Make sure the required cable (USB, serial, LAN) is connected from the PC to the Aspire S/Aspire system. 2.When using a LAN connection, skip to Step 5.
When using a connection other than a LAN, you must first connect to the Aspire using the dial-up connection. If not already connected, click on START SETTINGS NETWORK CONNECTIONS select the dial up connection to be used to connect to the Aspire system.
3.In the window that appears, if the user name and password are acceptable, click CONNECT or DIAL depending on your connection type.
Only one person is allowed in programming mode at a time. An error message will be received if trying to log in while another user is already in programming mode.
4.If the PRE-DIAL TERMINAL SCREEN option was selected in the dial-up setting, when it appears, left click on the black area of that screen. Type AT and press ENTER. Once OK has been displayed, click on CONTINUE and wait for the computer to connect to the Aspire system.
If an OK does not appear on the screen, continue to type AT and then press enter until you get an OK on the screen.
5.Once the connection has been established, with either Internet Explorer or Netscape Navigator installed, open the internet
browser application.
6.Enter the IP address of the Aspire system (example: http://192.78.0.1). This address is selected based on the type of con- nection to the Aspire.
Station Message Detail Recording
Station Message Detail Recording
SMDR provides a printed record of your calls.
Description
DSX | Features | 527
Station Message Detail Recording (SMDR) provides a record of the system’s outside calls. Typically, the record outputs to a customer-provided printer, terminal or SMDR data collection device. SMDR allows you to monitor the usage at each extension and line. This makes charge-back and traffc management easier. SMDR includes both incoming and outgoing calls, and can be turned off system-wide or selectively for each line.
The SMDR call record outputs when the call completes. The system assigns the SMDR record to the last extension on the call. For example, if extension 306 answers the call, talks for 20 minutes, and then transfers the call to extension 302, extension 302 “owns” the entire call record as soon as they hang up.
SMDR requires a customer-provided data collection device connected to the system’s RS-232 port. The default baud rate is 38,400. The data format is fxed at 8 data bits, no parity, with one stop bit (8N1). Connection requires:
• Adaptor P/N 1091014 to connect to the 9-pin RS-232 port on the data collection device.
• A standard 6-conductor line cord to connect the adaptor to the system’s RS-232 port.
SMDR does not buffer records when the data collection device is disconnected.
Call Duration Independent of System Clock
The duration of a call on the SMDR report is calculated independently of the system clock. This prevents changes made to the system Time and Date from inaccurately reporting the call duration after the Time and Date change. The automatic Daylight Savings Time adjustment also will not affect the call duration.
Battery Backup
Battery Backup
The system provides permanent backup of system memory.
Description
DSX
In the event of commercial AC power failure, the NAND Flash memory on the CPU PCB permanently maintains the site database. Additionally, an internal battery on the CPU provides short-term backup of the system date and time (Real Time Clock) and certain station parameters (such as the Caller ID log). The battery will hold the Real Time Clock and station parameters for up to 10-14 days. When commercial AC power is restored, the system restarts with all programming and the time and date intact.
Additional Battery Backup capability can be provided by a customer-supplied Uninterruptable Power Supply (UPS). The length of time the UPS will power the system when power fails depends on the capacity of the UPS unit. Consult with the UPS manufacturer for the specifcs. Refer to the Hardware Manual for additional details.
Voice recorder
A voltmeter is helpful in determining if your inputs are “wet loops” or dry lines. Wet loops typically carry -48V DC when measured off-hook. Wet loops are used to connect to your telecom provider, to your PBX, or to analog phone extensions. Dry lines such as headsets, radios, microphones and speakers carry audio, but no DC signaling voltage.
After you’ve determined a line type (either wet-loop or dry line), select a recording trigger: either Loop Start or VOX. Outside wet loops and inside analog extensions normally use Loop Start signaling. All dry lines use VOX signaling to trigger recording.
VOX Recording for Dry Lines
To bridge a dry line using Voice Operated Switch (VOX):
• Note: VOX mode is used for dry lines (lines that do not carry signaling voltage). Examples are handset connections, headsets, radios, microphones and speakers.
• Use a punch-down block, handset Y connector, breakout box, or RJ- 11 octopus cable to connect each line (two twisted wires) to the logger. Each of the logger inputs connects in “bridge” fashion across the existing wiring.
• Verify that the line audio level is within telecom specifications. Peak level should not exceed +3dBm. Gain controls should be set so that recording levels do not exceed 0dBm. Use Level Boost only if the input level is below -20dBm. If the VU meter peaks, the line level is too high. Reduce it using the manual gain controls, turn off Level Boost, and/or switch Auto Level on.
• Use Level Boost for handsets, microphones, and low-level signals only.
• Rename the line label by clicking on the line name. Type the new name and press Enter. For example, a handset tap or analog extension connected to LINE 01 might be renamed “Support Desk.”
• Set the line configuration mode to VOX by clicking on the line mode.
PAGING Internal,External & All Call Page
PAGING Internal,External & All Call Page
Description
A station, which is permitted to access page facilities, can connect and transmit voice announcements to any or all of the systems Internal,External Page zones. Stations are grouped into “zones” to receive pages to the zone. Stations not assigned to any zone will not receive a page including All Call pages.
A page warning tone, if assigned, will be provided to the Page Zone(s) prior to the audio connection. The user is allowed to continue the page for the specified Page Time-out timer after which the user is disconnected and the Page Zone(s) is returned to idle
Do Not Disturb Override
Do Not Disturb Override
Easily override a co-worker’s Do Not Disturb.
Description
Do Not Disturb Override lets an extension user override another extension’s Do Not Disturb. This allows a priority employee (such as a supervisor or executive) to get through to a co-worker right away while the co-worker’s phone is in Do Not Disturb. DND Override is available to all extensions that have DND Override set in their Class of Service. It is also available to any extension that has a Hotline key for a co-worker, even without the Class of Service option enabled.